Tests
ID | Test Type |
Tests |
Results |
Lab |
---|---|---|---|---|
1 |
Combustibility Twenty-Flve Foot Tunnel Furnace Test |
|
Flame spread value 0 Smoke density factor 0 Fuel contribute 0 Test extended to 30 minutes |
Hardwood Plywood Manufacturers Association Tested in P .0. BOX 2789 |
2 |
Fire Proof 2 hr Test |
ASTM E814 / UL 1479 CT State Building Inspector New York City MEA 68-91-M |
The initial ambient temperature was 57°F.
Hose Stream Test: No holes formed in the unexposed side of the sample after being exposed to the hose stream for 24 seconds. F Rating: 120 minutes The sample met the acceptance criteria of the "F Rating" for 120 Minutes per ASTM E814/UL 1479 specifications. |
V-TEC Lab Inc. |
3 |
Formaldehyde & VOC Test |
ASTM D5116 Connecticut Maryland |
The emissions test results indicate that neither formaldehyde nor volatile organic compounds are emitted from the airKrete insulation at 24 hours and 96 hours from manufacture. | ORTECH Environmental |
4 |
Mold Growth Test | ASTM Guideline D 6329-98 | Results show that the AirKrete Insulation Sample was resistant to mold growth at both 75% and 95% relative humidities. Neither molds were found to amplify in the materials at either humidity. | Air Quality Sciences |
5 |
Shrinkage Test | ASTM C951 | No Shrinking - After spraying 40 days at 75% and 50% relative humidity | Twin City Testing |
6 |
Sound Test | ASTM E90 | For any pair of rooms and microphone system, the 95% confidence interval TL, for transmission
loss must be less than the following.
Range of Transmission Loss
One-Third Octave Uncertainty, dB
Bands Required Actual 125 and 160 3 <1.5 200 and 250 2 <1.5 315 - 4000 1 <1 |
INTERTEK |
7 |
Thermal Conductivity Test | Thermal Conductivity | Dynalene Inc. Laboratory
Johnson H Robinson Testing Inc. |
|
8 |
Water Permeability Test | ASTM E96 / E96M - 10 | 0.3701cm/S Standard Test Methods for Water Vapor Transmission of Materials | V-TEC Lab Inc. |